Illumina sequencers available at NSC

We offer Illumina sequencing on Novaseq X, NextSeq 500 , MiSeq i100 and MiSeq instruments. Find specifications for the Illumina sequencing platforms below. 

 

MiSeq (Link to Illumina specs: Miseq)

Applications: Small genome DNA sequencing (de novo & resequencing), Metagenomics studies (including rDNA), Amplicon sequencing, Targeted resequencing such as gene panels, Control of libraries for large projects, smallRNA/microRNA sequencing, Epigenetic studies with few samples.

Sequencer/Run typeRead lengthOutput per runNSC guarantee
reads per end (M)Bases (Gb)reads per end (M)
MiSeq v375 PE22 - 253.3 - 3.810*
300 PE13 - 15
Miseq v250 SR12 - 150.7 - 0.86*
25 PE0.7 - 0.8
150 PE4.5 - 5.1
250 PE7.5 - 8.5
MiSeq v2 Micro150 PE41.22*
MiSeq v2 Nano150 PE10.30.5*
250 PE0.5

 

MiSeq i100 (Link to Illumina specs: MiSeq i100)

The MiSeq i100 is primarily used for small- to medium-scale sequencing projects that require fast turnaround and high accuracy. Its main applications include targeted sequencing (such as amplicon and gene panels), small genome sequencing (bacteria, viruses, plasmids), and mitochondrial DNA sequencing. It is also commonly used for amplicon-based metagenomics (e.g. 16S/ITS) and small RNA-seq or pilot transcriptomics studies. Can also be used as a control of libraries or pooling for larger projects.

Flow cellRead lengthOutput per runNSC guarantee
reads per end (M)Bases (Gb)reads per end (M)
      5M150 PE51.52.5*
300 PE3
     25M100 SR / 50 PE252.512.5*
150 PE7.5
300 PE15
      500 PE25
      50M100 SR / 50 PE50525*
150 PE15
300 PE30
     100M    100 SR/50 PE1001050*
150 PE30

 

NextSeq 500 (Link to Illumina specs: NextSeq)

Applications: Genomic DNA sequencing, Exome sequencing, mRNA sequencing, smallRNA/microRNA sequencing, Epigenetics, ChIP-seq, DNA methylation, Small genome DNA sequencing (de novo & resequencing), Targeted resequencing such as gene panels.

Sequencer/Run typeRead lengthOutput per runNSC guarantee
reads per end (M)Bases (Gb)reads per end (M)

NextSeq High

Output

75 SE40025 - 30200*
75 PE50 - 60
150 PE100 - 120

NextSeq Mid

Output

75 PE13016 - 1965*
150 PE32 - 39

 

NovaSeq X (Link to Illumina specs: NovaSeq X)

The NovaSeq X flowcells 10B and 25B can be split into 8 separate lanes, and the 1.5B flowcell into 2 lanes. We will run half or 1/8 flow cells only when we have enough other projects to fill the flow cell, but are running the 1.5B and 25B, read length 150 bp PE, on a regular basis.  

Applications: Genomic DNA sequencing, Metagenomics, Exome sequencing, mRNA sequencing, smallRNA/microRNA sequencing, Epigenetics, ChIP-seq, DNA methylation.

 

    Flow cell

Read lengthOutput perm runNSC guarantee
reads per end (M)Bases (Gb)reads per end (M)

 

NovaSeq X 1.5B

 

    50 PE1600 (800 per lane)     165 800* (400 per lane)
   100 PE     330
   150 PE     500
   300 PE   1 000
NovaSeq x 10B    50 PE10 000 (1 200 per lane)   1 0005000* (600 per lane)
   100 PE   2 000
   150 PE   3 000
NovaSeq X 25B    50 PE26 000 (3 250 per lane)   2 50013 000* (1 600 per lane)
   100 PE   5 500
   150 PE   8 000

 

 

Data output performance guarantees

If your samples are submitted in accordance with our guidelines and meet our quality and quantity requirements, we provide the performance guarantees given in the table. Note that these are our minimal output criteria and we routinely expect greater output. Should we fail to meet these targets, we will run additional sequencing at no cost to you or offer a discount as appropriate. In the case of multiplexed samples, we cannot guarantee equal distribution of reads between different indexes, but we do run a qPCR assay to achieve this as best possible.

*Exceptions: Data guarantees are not valid for long-insert libraries (insert size > 500 bp) and low-diversity samples (e.g. PCR amplicons, restriction digestion fragments, RAD libraries), which require dilution and blending with control library using Illumina technology.

Note that if your submitted samples do not meet our quality or quantity criteria, we may still be willing to attempt sample prep and sequencing, but our performance guarantee no longer applies and you will be liable for all expenses incurred regardless of the output amount, also in the event that no sequence data can be generated.

 

PhiX blending

It is standard practice to spike Illumina sequencing runs with 1% PhiX library, which acts as a reference for sequencing performance. The level of PhiX blend must be increased for low-diversity samples, up to 50%, at the expense of yield. If you are concerned that the use of PhiX will cause problems for your downstream data analysis, it is your responsibility to tell us this and request an alternative solution.